Control Samples
1999 Raw Milk Infrared Control Samples – Use Guide for Order 124/135
Handlers Introduction In January of 1999, the Seattle Market Administrator developed a raw milk infrared control sample program for the benefit of federal order 124 and 131 handlers subject to pay test verification. Participation in the program is strictly voluntary and there is no direct charge for this service. This guide is intended for all laboratory managers. It describes the nature of the new control samples and how handler labs can derive maximum benefit from their usage. Sample Description Number of samples: 12
Recommended Usage Parameters (based on Seattle MA Lab protocols) Tempering temperature: 108oF (42oC) Daily Calibration Check – possible approaches {Handler labs differ widely in their calibration procedures. A few calibrate daily using a sophisticated array of controls and in-house pilot samples. Others calibrate biweekly using commercially available controls. The options listed below illustrate the broad range of approaches possible given a new MA control set. Since the MA cannot supply enough controls for daily calibration (the most rigorous approach), all lab managers who choose to use the new controls should consider how to ensure the accuracy of their particular IR between weekly (or biweekly) formal calibrations.} optimum: daily calibration on MA controls (as performed by Seattle Lab) approach A: weekly MA-based calibration immediately followed by a run of raw milk check samples (check samples should possess good range and must be stable over a week). The same check samples are then run first thing daily. If there is a sufficient number of check samples (e.g. 6-10), mathematical adjustments to slope and bias can be made whenever necessary. If check samples are few (e.g. 3-5) and a drift is indicated, recalibration using MA controls may be warranted. approach B: same as option A but with biweekly MA-based calibration. Spare MA set is reserved for a marked shift (e.g. due, for example, to instrument service). approach C: weekly or biweekly MA-based calibration with no daily checks other than intermittent check or "pilot" samples (e.g. use of a large stock of raw or homogenized milk every 30 minutes). This option recommended only if IR is demonstrably stable. An unusual shift in check sample or pilot should signal a recalibration. Evaluation of Control Sample and IR Performance With each biweekly reference chemistry mailing, you will find a questionnaire page relating to your IR calibration. This is a completely optional service. You may:
In principle, regular use of the questionnaire (or similar records of your own) can be used for
MA Contacts For general questions, missing reference chemistry, replacement/additional control samples, sample integrity problems (e.g. leakers, cracked vials, too warm) , incorrect or altered shipping information Please call: Seattle MA Lab For: Shipping containers (PLEASE RETURN BOXES BIWEEKLY via FEDEX to CLEVELAND!) Ship to: Bob Malinak USDA-AMS-Mideast
FMMA Lab
Use FEDEX Priority Overnight or Standard Overnight Bill to: third party, call Seattle MA Lab @ 1(877)
252-9557 (if you prefer to use another carrier (e.g. UPS ground), this is fine, however, the Seattle MA office will only cover FEDEX shipping charges)
For Lost shipments Please call: Cleveland MA Lab (Bob Malinak - control sample